Print View
|
Windsor Windows and Doors
|
453-H-001.06
| Pinnacle Clad Awning | Clad Awning | Class CW-PG30; Size Tested 1524mm x 1524mm Type-AP; DP +30/-30 psf; Water Test Press 220Pa (4.59psf); Can. Air Infil/Exfil. Level=A3 | 101/I.S.2/A440-17 |
Print View
|
Windsor Windows and Doors
|
453-H-001.07
| Pinnacle Clad Awning | Clad Awning | Class CW-PG40; Size Tested 1219 mm x 914 mm Type-AP; DP +40/-40 psf; Water Test Press 290Pa (6.06psf); Can. Air Infil/Exfil. Level=A3 | 101/I.S.2/A440-17 |
Print View
|
Windsor Windows and Doors
|
453-H-001.08
| Pinnacle Clad Awning | Clad Awning 4432 HP Impact | Class LC-PG50; Size Tested 1219 mm x 914 mm Type-AP; DP +50/-50 psf; Water Test Press 360Pa (7.52psf); Can. Air Infil/Exfil. Level=A2 | 101/I.S.2/A440-17 |
Print View
|
Windsor Windows and Doors
|
453-H-001.09
| Pinnacle Clad Awning | Clad Awning 4432 HP Impact | DP +50/-50 psf, Missile D, Wind Zone 3 | ASTM E-1996-20 / ASTM E-1886-19 |
Print View
|
Windsor Windows and Doors
|
453-H-002.00
| Pinnacle Clad Casement | Clad Casement | Class R-PG30; Size Tested 914mm x 1829 Type-C; DP +30/-30 psf; Water Test Press 220Pa (4.59psf); Can. Air Infil/Exfil. Level=A3 | 101/I.S.2/A440-11 |
Print View
|
Windsor Windows and Doors
|
453-H-002.03
| Pinnacle Clad Casement | Clad Casement | Class R-PG30; Size Tested 711mm x 2134mm * Type-C; DP +30/-30 psf; Water Test Press 220Pa (4.59psf); Can. Air Infil/Exfil. Level=A3 | 101/I.S.2/A440-11 |
Print View
|
Windsor Windows and Doors
|
453-H-002.04
| Pinnacle Clad Casement | Clad Casement | Class R-PG30; Size Tested 914mm x 1829mm * Type-C; DP +30/-30 psf; Water Test Press 220Pa (4.59psf); Can. Air Infil/Exfil. Level=A2 | 101/I.S.2/A440-11 |
Print View
|
Windsor Windows and Doors
|
453-H-002.05
| Pinnacle Clad Casement | Clad Casement | Class R-PG50; Size Tested 711mm x 1981mm * Type-C; DP +50/-50 psf; Water Test Press 360Pa (7.52psf); Can. Air Infil/Exfil. Level=A3 | 101/I.S.2/A440-11 |
Print View
|
Windsor Windows and Doors
|
453-H-002.06
| Pinnacle Clad Casement | Clad Casement | Class LC-PG50; Size Tested 914mm x 1829mm * Type-C; DP +50/-50 psf; Water Test Press 360Pa (7.52psf); Can. Air Infil/Exfil. Level=A2 | 101/I.S.2/A440-11 |
Print View
|
Windsor Windows and Doors
|
453-H-002.07
| Pinnacle Clad Casement | Clad Casement | Class R-PG50; Size Tested 711mm x 2134mm * Type-C; DP +50/-50 psf; Water Test Press 360Pa (7.52psf); Can. Air Infil/Exfil. Level=A3 | 101/I.S.2/A440-11 |
Print View
|
Windsor Windows and Doors
|
453-H-002.10
| Pinnacle Clad Casement | Clad Casement | Class LC-PG40; Size Tested 1067mm x 1524mm Type-C; DP +40/-40 psf; Water Test Press 290Pa (6.06psf); Can. Air Infil/Exfil. Level=A2 | 101/I.S.2/A440-11 |
Print View
|
Windsor Windows and Doors
|
453-H-002.12
| Pinnacle Clad Casement | Clad Casement | DP +50/-50 psf, Missile D, Wind Zone 3 | ASTM E-1996 12/ASTM E-1886-05 |
Print View
|
Windsor Windows and Doors
|
453-H-002.13
| Pinnacle Clad Casement | Clad Casement | Class R-PG30; Size Tested 1829mm x 2438mm * Type-C; DP +30/-30 psf; Water Test Press 330Pa (6.89psf) | AAMA 450-10 |
Print View
|
Windsor Windows and Doors
|
453-H-002.14
| Pinnacle Clad Casement | Clad Casement Picture Mulled over Casement Mulled 2 wide | Class R-PG30; Size Tested 1829mm x 2438mm * Type-MA; DP +30/-30 psf; Water Test Press 330Pa (6.89psf) | AAMA 450-10 |
Print View
|
Windsor Windows and Doors
|
453-H-002.15
| Pinnacle Clad Casement | Clad Casement | Class R-PG50; Size Tested 1067mm x 1219mm * Type-C; DP +50/-50 psf; Water Test Press 360Pa (7.52psf); Can. Air Infil/Exfil. Level=A3 | 101/I.S.2/A440-11 |
Print View
|
Windsor Windows and Doors
|
453-H-002.17
| Pinnacle Clad Casement | Clad Casement | Class R-PG50; Size Tested 1067mm x 1219mm * Type-C; DP +2400/-2400Pa; Water Test Press 360Pa; Can. Air Infil/Exfil. Level=A3 | CSA A440 S1-09 |
Print View
|
Windsor Windows and Doors
|
453-H-002.18
| Pinnacle Clad Casement | Clad Casement | Class LC-PG40; Size Tested 1067mm x 1524mm * Type-C; DP +1920/-1920Pa; Water Test Press 290Pa; Can. Air Infil/Exfil. Level=A3 | CSA A440 S1-09 |
Print View
|
Windsor Windows and Doors
|
453-H-002.19
| Pinnacle Clad Casement | Clad Casement | Class LC-PG40; Size Tested 762 mm x 1829 mm * Type-C; DP +40/-40 psf; Water Test Press 290Pa (6.06psf); Can. Air Infil/Exfil. Level=A3 | 101/I.S.2/A440-17 |
Print View
|
Windsor Windows and Doors
|
453-H-002.20
| Pinnacle Clad Casement | Clad Casement | Class LC-PG40; Size Tested 762 mm x 1829 mm * Type-C; DP +1920/-1920 Pa; Water Test Press 290Pa ; Can. Air Infil/Exfil. Level=A3 | CSA A440 S1-09 |
Print View
|
Windsor Windows and Doors
|
453-H-002.21
| Pinnacle Clad Casement | Clad Casement DP Upgrade | Class LC-PG65; Size Tested 762 mm x 1829 mm * Type-C; DP +65/-65 psf; Water Test Press 470Pa (9.82psf); Can. Air Infil/Exfil. Level=A2 | 101/I.S.2/A440-17 |
Print View
|
Windsor Windows and Doors
|
453-H-002.22
| Pinnacle Clad Casement | Clad Casement DP Upgrade | Class LC-PG65; Size Tested 762 mm x 1829 mm * Type-C; DP +3120/-3120 Pa; Water Test Press 470Pa ; Can. Air Infil/Exfil. Level=A2 | CSA A440 S1-09 |
Print View
|
Windsor Windows and Doors
|
453-H-002.23
| Pinnacle Clad Casement | Clad Casement DP Upgrade 3672 | Class LC-PG50; Size Tested 914 mm x 1829 mm Type-C; DP +50/-50 psf; Water Test Press 360Pa (7.52psf); Can. Air Infil/Exfil. Level=A2 | 101/I.S.2/A440-17 |
Print View
|
Windsor Windows and Doors
|
453-H-002.24
| Pinnacle Clad Casement | Clad Casement DP Upgrade 3672 | Class LC-PG50; Size Tested 914 mm x 1829 mm Type-C; DP +2400/-2400 Pa; Water Test Press 360Pa; Can. Air Infil/Exfil. Level=A2 | CSA A440 S1-09 |
Print View
|
Windsor Windows and Doors
|
453-H-002.25
| Pinnacle Clad Casement | Clad Casement DP Upgrade 2480 | Class LC-PG50; Size Tested 711 mm x 2134 mm * Type-C; DP +50/-50 psf; Water Test Press 360Pa (7.52psf); Can. Air Infil/Exfil. Level=A3 | 101/I.S.2/A440-17 |
Print View
|
Windsor Windows and Doors
|
453-H-002.26
| Pinnacle Clad Casement | Clad Casement DP Upgrade 2480 | Class LC-PG50; Size Tested 711 mm x 2134 mm * Type-C; DP +2400/-2400 Pa; Water Test Press 360Pa; Can. Air Infil/Exfil. Level=A3 | CSA A440 S1-09 |
Print View
|
Windsor Windows and Doors
|
453-H-002.27
| Pinnacle Clad Casement | Clad Casement 2480 | Class LC-PG30; Size Tested 711 mm x 2134 mm * Type-C; DP +30/-30 psf; Water Test Press 220Pa (4.59psf); Can. Air Infil/Exfil. Level=A2 | 101/I.S.2/A440-17 |
Print View
|
Windsor Windows and Doors
|
453-H-002.28
| Pinnacle Clad Casement | Clad Casement 2480 | Class LC-PG30; Size Tested 711 mm x 2134 mm * Type-C; DP +1440/-1440 Pa; Water Test Press 220Pa; Can. Air Infil/Exfil. Level=A2 | CSA A440 S1-09 |
Print View
|
Windsor Windows and Doors
|
453-H-002.29
| Pinnacle Clad Casement | Clad Casement 2668 HP WZ4 | Class LC-PG65; Size Tested 762 mm x 1829 mm * Type-C; DP +65/-65 psf; Water Test Press 470Pa (9.82psf); Can. Air Infil/Exfil. Level=A2 | 101/I.S.2/A440-17 |
Print View
|
Windsor Windows and Doors
|
453-H-002.30
| Pinnacle Clad Casement | Clad Casement 2668 HP WZ4 | DP +65/-65 psf: Missile D, Wind Zone 4 | ASTM E-1996-20 / ASTM E-1886-19 |
Print View
|
Windsor Windows and Doors
|
453-H-002.31
| Pinnacle Clad Casement | Clad Casement 3672 | Class LC-PG30; Size Tested 914 mm x 1829 mm Type-C; DP +30/-30 psf; Water Test Press 220Pa (4.59psf); Can. Air Infil/Exfil. Level=A2 | 101/I.S.2/A440-17 |
Print View
|
Windsor Windows and Doors
|
453-H-002.32
| Pinnacle Clad Casement | Clad Casement 2474 | Class LC-PG40; Size Tested 28.000 in x 78.000 in * Type-C; DP +40/-40 psf; Water Test Press 290Pa (6.06psf); Can. Air Infil/Exfil. Level=A2 | 101/I.S.2/A440-17 |
Print View
|
Windsor Windows and Doors
|
453-H-002.33
| Pinnacle Clad Casement | Clad Casement 2474 DP Upgrade | Class LC-PG50; Size Tested 28.000 in x 78.000 in * Type-C; DP +50/-50 psf; Water Test Press 360Pa (7.52psf); Can. Air Infil/Exfil. Level=A2 | 101/I.S.2/A440-22 |
Print View
|
Windsor Windows and Doors
|
453-H-002.34
| Pinnacle Clad Casement | Clad Casement 3856 | Class LC-PG40; Size Tested 42.000 in x 60.000 in * Type-C; DP +40/-40 psf; Water Test Press 290Pa (6.06psf); Can. Air Infil/Exfil. Level=A3 | 101/I.S.2/A440-22 |
Print View
|
Windsor Windows and Doors
|
453-H-003.00
| Pinnacle Clad Bi-Fold Door | Clad Bi-Fold Door | Class LC-PG30; Size Tested 2813mm x 3070mm Type-SHD; DP +30/-30 psf; Water Test Press 220Pa (4.59psf); Can. Air Infil/Exfil. Level=A2 | 101/I.S.2/A440-11 |
Print View
|
Windsor Windows and Doors
|
453-H-004.06
| Pinnacle Clad Door Transom In Sash | Impact Pinnacle Clad Transom | Class LC-PG50; Size Tested 1905mm x 610mm Type-TR; DP +50/-65 psf; Water Test Press 360Pa (7.52psf); Can. Air Infil/Exfil. Level=Fixed | 101/I.S.2/A440-17 |
Print View
|
Windsor Windows and Doors
|
453-H-004.07
| Pinnacle Clad Door Transom In Sash | Impact Pinnacle Clad Transom | DP +50/-65 psf, Missile D, Wind Zone 4 | ASTM E1996-14a/ ASTM E-1886-13a |
Print View
|
Windsor Windows and Doors
|
453-H-004.08
| Pinnacle Clad Door Transom In Sash | Impact Pinnacle Clad Transom | DP +50/-65 psf, | TAS 201/202/203-94 |
Print View
|
Windsor Windows and Doors
|
453-H-004.09
| Pinnacle Clad Door Transom In Sash | Pinnacle Clad Transom | Class CW-PG50; Size Tested 1830mm x 610mm * Type-TR; DP +50/-50 psf; Water Test Press 360Pa (7.52psf); Can. Air Infil/Exfil. Level=Fixed | 101/I.S.2/A440-17 |
Print View
|
Windsor Windows and Doors
|
453-H-004.10
| Pinnacle Clad Door Transom In Sash | Pinnacle Clad Transom | Class LC-PG50; Size Tested 2743 mm x 610 mm Type-TR; DP +50/-50 psf; Water Test Press 360Pa (7.52psf); Can. Air Infil/Exfil. Level=Fixed | 101/I.S.2/A440-17 |
Print View
|
Windsor Windows and Doors
|
453-H-004.11
| Pinnacle Clad Door Transom In Sash | Pinnacle Clad Transom | Class LC-PG50; Size Tested 2743 mm x 610 mm Type-TR; DP +2400/-2400 Pa; Water Test Press 360Pa ; Can. Air Infil/Exfil. Level=Fixed | CSA A440 S1-09 |
Print View
|
Windsor Windows and Doors
|
453-H-005.00
| Pinnacle Clad Casement Picture | Clad Casement Picture | Class CW-PG45; Size Tested 1829mm x 2134mm Type-FW; DP +/-45 psf; Water Test Press 320Pa (6.90psf); Can. Air Infil/Exfil. Level=Fixed | 101/I.S.2/A440-11 |
Print View
|
Windsor Windows and Doors
|
453-H-005.03
| Pinnacle Clad Casement Picture | Clad Casement Picture | Class LC-PG50; Size Tested 1524mm x 1524mm * Type-FW; DP +50/-50 psf; Water Test Press 360Pa (7.52psf); Can. Air Infil/Exfil. Level=Fixed | 101/I.S.2/A440-11 |
Print View
|
Windsor Windows and Doors
|
453-H-005.06
| Pinnacle Clad Casement Picture | Clad Casement Picture mulled to Clad Casements | Class R-PG50; Size Tested 3658mm x 1829mm * Type-MA; DP +50/-50 psf, Wind Zone 4; Water Test Press 360Pa (7.52psf); Can. Air Infil/Exfil. Level=Fixed | AAMA 450-10 |
Print View
|
Windsor Windows and Doors
|
453-H-005.07
| Pinnacle Clad Casement Picture | Clad Casement Picture mulled to Pinnacle Clad Casement | Class R-PG50; Size Tested 3251mm x 1981mm * Type-MA; DP +50/-50 psf, Wind Zone 4; Water Test Press 360Pa (7.52psf); Can. Air Infil/Exfil. Level=Fixed | AAMA 450-10 |
Print View
|
Windsor Windows and Doors
|
453-H-005.11
| Pinnacle Clad Casement Picture | Clad Casement Picture | Class CW-PG40; Size Tested 1829mm x 1981mm * Type-FW; DP +40/-40 psf; Water Test Press 290Pa (6.06psf); Can. Air Infil/Exfil. Level=Fixed | 101/I.S.2/A440-11 |
Print View
|
Windsor Windows and Doors
|
453-H-005.12
| Pinnacle Clad Casement Picture | Clad Casement Picture | Class CW-PG40; Size Tested 1829mm x 1981mm * Type-FW; DP +1920/-1920Pa; Water Test Press 290Pa; Can. Air Infil/Exfil. Level=Fixed | CSA A440 S1-09 |
Print View
|
Windsor Windows and Doors
|
453-H-005.15
| Pinnacle Clad Casement Picture | Clad Casement Picture | Class CW-PG40; Size Tested 1829mm x 1981mm Type-FW; DP +40/-40 psf; Water Test Press 290Pa (6.06psf); Can. Air Infil/Exfil. Level=Fixed | 101/I.S.2/A440-08 |
Print View
|
Windsor Windows and Doors
|
453-H-005.16
| Pinnacle Clad Casement Picture | Clad Casement Picture | Class CW-PG40; Size Tested 1372 mm x 1981 mm * Type-FW; DP +40/-40 psf; Water Test Press 290Pa (6.06psf); Can. Air Infil/Exfil. Level=Fixed | 101/I.S.2/A440-17 |
Print View
|
Windsor Windows and Doors
|
453-H-005.17
| Pinnacle Clad Casement Picture | Clad Casement Picture | Class LC-PG65; Size Tested 1219 mm x 1829 mm * Type-FW; DP +65/-65 psf; Water Test Press 470Pa (9.82psf); Can. Air Infil/Exfil. Level=Fixed | 101/I.S.2/A440-17 |
Print View
|
Windsor Windows and Doors
|
453-H-005.18
| Pinnacle Clad Casement Picture | Clad Casement Picture | Class LC-PG65; Size Tested 1219 mm x 1829 mm * Type-FW; DP +3120/-3120 Pa; Water Test Press 470Pa ; Can. Air Infil/Exfil. Level=Fixed | CSA A440 S1-09 |